!COUPLE¶
Definition of coupled surface (Used only in coupled analysis)
Parameter¶
TYPE = 1: One-way coupling (FrontISTR starts by receiving data)
2: One-way coupling (FrontISTR starts by sending data)
3: Staggered two-way coupling (FrontISTR starts by receiving data)
4: Staggered two-way coupling (FrontISTR starts by sending data)
5: Iterative partitioned two-way coupling (FrontISTR starts by receiving data)
6: Iterative partitioned two-way coupling (FrontISTR starts by sending data)
ISTEP = Number of steps
From the start of the analysis through the number of steps specified here, the fluid force is increased by multiplying it by a linear function from 0 to 1,
and thereafter the input fluid force is applied as-is
WINDOW => 0 : Apply the fluid force multiplied by the window function (*)
(*) \(\frac{1}{2}(1 - \cos\frac{2\pi i}{N}),(i: current step, N: total number of steps in the current analysis)\)
** 2nd line or later **
| Parameter Name | Attributions | Contents |
|---|---|---|
| SURFACE_ID | C | Surface group name |