!ELEMENT_ACTIVATION¶
Elementlarni faollashtirish/nofaollashtirishni aniqlash
Parametrlar¶
MODE = boshqaruv rejimi (FIXED, AMPLITUDE, DAMAGE) [majburiy]
STATE = element holati (ON: faol, OFF: nofaol) (MODE=FIXED bo‘lganda majburiy)
AMP = amplituda nomi (MODE=AMPLITUDE bo‘lganda majburiy)
MEASURE = baholash kattaligi (STRESS, STRAIN) (MODE=DAMAGE bo‘lganda majburiy)
EPSILON = soxta qattiqlik koeffitsiyenti (sukut bo‘yicha: 1.0E-6)
GRPID = boshqaruv guruhi ID si
** 2-qator va undan keyingi qatorlar **
MODE = FIXED, AMPLITUDE bo‘lganda¶
MODE = DAMAGE bo‘lganda¶
| O‘zgaruvchi nomi | Atribut | Tavsif |
|---|---|---|
| ELEM_GRP_NAME | C | Element guruhi nomi |
| LOWER | R | Kuchlanish/deformatsiyaning quyi chegarasi |
| UPPER | R | Kuchlanish/deformatsiyaning yuqori chegarasi |
Foydalanish misoli¶
!ELEMENT_ACTIVATION, MODE=FIXED, STATE=OFF, EPSILON=1.0E-3, GRPID=1
PART_1
!ELEMENT_ACTIVATION, MODE=AMPLITUDE, AMP=AMP1, EPSILON=1.0E-3, GRPID=2
PART_2
!ELEMENT_ACTIVATION, MODE=DAMAGE, MEASURE=STRESS, EPSILON=1.0E-6, GRPID=3
PART_3, 100.0, 200.0
!STEP, SUBSTEPS=10
BOUNDARY,1
LOAD,1
!STEP, SUBSTEPS=10
BOUNDARY,1
LOAD,1
ELEMACT,1
!STEP, SUBSTEPS=10
BOUNDARY,1
LOAD,1
ELEMACT,1
ELEMACT,2
Izohlar¶
MODEyordamida xatti-harakatni o‘zaro istisno rejimlardan biri sifatida belgilang (MODE=FIXED|AMPLITUDE|DAMAGE).MODE=FIXEDbo‘lgandaSTATE=ON/OFFbilan elementlar doimo faol/nofaol ekanini belgilang.MODE=AMPLITUDEbo‘lganda amplituda qiymatiga qarab faol/nofaol holatni almashtiring (amp_val > 0.5bo‘lsa faol, aks holda nofaol).MODE=DAMAGEbo‘lgandaMEASURE=STRESS|STRAINbilan ko‘rsatilgan kattalik diapazondan tashqariga chiqqan (LOWER ≤ qiymat ≤ UPPER shartini qanoatlantirmagan) elementlar nofaol qilinadi. Nofaol qilingandan keyin ular qayta faollashtirilmaydi.- GRPID bilan ko‘rsatilgan boshqaruv guruhi
!STEPichidagiELEMACT, idorqali yoqiladi. - Agar
!STEPichidaELEMACT, idko‘rsatilmasa, tegishli element-faollashtirish sozlamasi qo‘llanmaydi.