!ELEMENT_ACTIVATION¶
Ufafanuzi wa kuwezesha/kulemaza elementi
Vigezo¶
MODE = hali ya udhibiti (FIXED, AMPLITUDE, DAMAGE) [lazima]
STATE = hali ya elementi (ON: imewezeshwa, OFF: imelemazwa) (lazima wakati MODE=FIXED)
AMP = jina la amplitude (lazima wakati MODE=AMPLITUDE)
MEASURE = kiasi cha uamuzi (STRESS, STRAIN) (lazima wakati MODE=DAMAGE)
EPSILON = coefficient ya dummy stiffness (chaguo-msingi: 1.0E-6)
GRPID = ID ya kikundi cha udhibiti
** Mstari wa 2 na kuendelea **
Ikiwa MODE = FIXED, AMPLITUDE¶
Ikiwa MODE = DAMAGE¶
| Jina la kigezo | Sifa | Maelezo |
|---|---|---|
| ELEM_GRP_NAME | C | Jina la kikundi cha elementi |
| LOWER | R | Kikomo cha chini cha mkazo/mgeuko |
| UPPER | R | Kikomo cha juu cha mkazo/mgeuko |
Mfano wa matumizi¶
!ELEMENT_ACTIVATION, MODE=FIXED, STATE=OFF, EPSILON=1.0E-3, GRPID=1
PART_1
!ELEMENT_ACTIVATION, MODE=AMPLITUDE, AMP=AMP1, EPSILON=1.0E-3, GRPID=2
PART_2
!ELEMENT_ACTIVATION, MODE=DAMAGE, MEASURE=STRESS, EPSILON=1.0E-6, GRPID=3
PART_3, 100.0, 200.0
!STEP, SUBSTEPS=10
BOUNDARY,1
LOAD,1
!STEP, SUBSTEPS=10
BOUNDARY,1
LOAD,1
ELEMACT,1
!STEP, SUBSTEPS=10
BOUNDARY,1
LOAD,1
ELEMACT,1
ELEMACT,2
Maelezo¶
- Tabia hubainishwa kwa njia ya kipekee kwa
MODE(MODE=FIXED|AMPLITUDE|DAMAGE). - Kwa
MODE=FIXED,STATE=ON/OFFhubainisha elementi iwe imewezeshwa/imelemazwa kila wakati. - Kwa
MODE=AMPLITUDE, elementi hubadilishwa kati ya kuwezeshwa/kulemazwa kulingana na thamani ya amplitude (imewezeshwa ikiwaamp_val > 0.5, vinginevyo imelemazwa). - Kwa
MODE=DAMAGE, elementi hulemazwa ikiwa kiasi kilichobainishwa kwaMEASURE=STRESS|STRAINkiko nje ya masafa (hakitoshelezi LOWER ≤ thamani ≤ UPPER). Baada ya kulemazwa haiwezeshwi tena. - Kikundi cha udhibiti kilichobainishwa kwa GRPID huwezeshwa kwa
ELEMACT, idndani ya!STEP. - Ikiwa
ELEMACT, idhaijabainishwa ndani ya!STEP, mpangilio husika wa uamilishaji wa elementi hautumiki.